Descrizione
XSA810 Portable Spectrum Analyzer Measuring Instrument Frequency Range 9kHZ‑1.00009GHZUK 100‑240V
Item Type: Spectrum Analyzer
Material: ABS
Main Function:
Display the spectrum, amplitude and frequency of the signal under test. It can be displayed in a panoramic view, or a bandwidth test can be selected.
XSA810
Frequency Range
9kHZ - 1.00009GHZ
Frequency Resolution
1HZ
Span
0HZ, 100HZ to the maximum frequency of the instrument
Span Uncertainty
± Span / (Sweep points-1)
Carrier Offset
10 kHz
<-80 dBc/Hz
100kHz
<-100 dBc/Hz
1MHz
<-115 dBc/Hz
Resolution Bandwidth (-3dB)
1 Hz - 1 MHz (1-3-5-10 steps)
Resolution Bandwidth Accuracy
<5% typical
Resolution filter shape factor (60 dB: 3 dB)
<5 typical
Video Bandwidth (-3dB)
10 Hz - 1 MHz (1-3-5-10 steps)
Amplitude Measurement Range
DANL to +10 dBm, 100 kHz - 10 MHz, preamplifier off
DANL to +20dBm, 10MHz to 1.5GHz, preamplifier off
Reference Level
-80dBm - +30dBm, step is 0.01dB
Preamplifier
20 dB, nominal, 100 kHz - 1.5 GHz
Input Attenuator
XSA805
0 - 40dB in 1dB steps
Display average noise level (attenuator is 0 dB, resolution bandwidth and video bandwidth are both 100 Hz, sampling detection, average number of traces ≥50, 20℃ to 30℃, input impedance is 50 Ω)
Preamplifier off
9 kHz - 1 MHz
-95dBm (typical value), <-88dBm
500MHz - 1GHz
-140dBm (typical value), <-130dBm
Preamplifier on
100 kHz - 1 MHz
-135dBm (typical value), <-128 dBm
500MHz - 1GHz
-160 dBm (typical value), <-150 dBm
Frequency Response (20℃ - 30℃, 30% - 70% relative humidity, input attenuation 10 dB, relative to 50 MHz)
Preamplifier Off (Fc≥9kHz)
<0.7 dB
Preamplifier On (Fc≥50 MHz)
<1.0 dB
Absolute Amplitude Accuracy
Uncertainty
fc = 50 MHz, peak detector, preamplifier off, attenuator is 10 dB, input signal level = -10 dBm, 20°C-30°C
<0.4dB
Tracking Source (Optional)
Output Level Range
-40 dBm - 0 dBm
Output Level Resolution
1 dB
Output Flatness
Relative to 50 MHz
± 3dB
Tracking Source Spurs
Harmonic spurs
-30 dBc (when the output power of the tracking generator is -10 dBm)
Non-Harmonic Spurs
-40 dBc (when the output power of the tracking generator is -10 dBm)
Tracking Source to Input Terminal
-60 dB (when the output power of the tracking source is 0 dBm)
Frequency Range
100 kHz - 1.000009 GHz
How e:
2: Connect the probe to the channel
3: The probe is calibrated in the 5V calibration area to see if the waveform is displayed completely
4: Adjust the probe so that the waveform can be output stably
5: Measurement
-
ID Fruugo:
413757861-874354881
-
EAN:
7891337911373