RD72-DC-12V Infinite Cycle ON OFF Relay Module Trigger Delay Switch Infinite Loop Relay

13,95 €
spedizione GRATUITA

RD72-DC-12V Infinite Cycle ON OFF Relay Module Trigger Delay Switch Infinite Loop Relay

  • Marchio: Unbranded
Venduto da:

RD72-DC-12V Infinite Cycle ON OFF Relay Module Trigger Delay Switch Infinite Loop Relay

  • Marchio: Unbranded
Prezzo di vendita consigliato: 17,95 €
Prezzo: 13,95 €
Risparmi: 4,00 € (22%)
Venduto da:
13,95 €
spedizione GRATUITA

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

Feature:1. With start / stop function, the module enters infinite cycle mode after starting, and the relay works on and off according to the set time.2. Infinite-cycle power-on and power-off modules, the delay time can be adjusted separately, the longest delay can be 1000min.3. Low power consumption of the control board, less than 1W.4. Start external wiring button: Passive switch input. The green light turns on after starting, and stays in the red light after stopping.5. The button is required to be unlocked (ie self-resetting). It can also be connected to external voltage signals. When the voltage is lower than 2V, it is low level. When the voltage is higher than 2V, it is high level. The maximum input should not exceed 30V.Specification:Item Type: Cyclic On-Off Relay ModuleVoltage: DC 12VPower Consumption: <1.0WOutput: Passive output (ie dry contact), a group of normally open + normally closed. Do not exceed 10A.Life: 100,000 operationsTime Range: 0.5 seconds-1000 minutesTime Accuracy: the maximum value of the range * 0.001, that is, 1000-level resolutionStart external wiring button: Passive switch input. The green light turns on after starting, and stays in the red light after stopping.The button is required to be unlocked (ie self-resetting). It can also be connected to external voltage signals. When the voltage is lower than 2V, it is low level. When the voltage is higher than 2V, it is high level. The maximum input should not exceed 30V.Wiring Terminal:<-- DC + Module power supply positive input<-- DC - Module power supply negative input--> NO Normally open contact wiring terminal--> COM Common contact wiring terminal of relay--> NO Normally closed contact terminal of the relay, generally not connected.Instructions: Time can be set in both power-on and power-off statesPlease refer to the detailed explanation of the actual photos and pictures later to understand the operation method more intuitively.1. ON time setting:The potentiometer under the RUN TIME mark adjusts the time, clockwise to increase the duration, and counterclockwise to shorten the duration.The left side of the down-dial switch of the potentiometer is the time range setting. The adjustable range of the adjustable resistor is 0-100 after dialing down; the range of 0-1000 after dialing up.The right side of the down-dial switch of the potentiometer is set in units. Dial down to Sec. For seconds; dial up to Min. For minutes.2. OFF duration setting:The potentiometer under the OFF TIME mark adjusts the time, clockwise to increase the duration, and counterclockwise to shorten the duration.The left side of the down-dial switch of the potentiometer is the time range setting. The adjustable range of the adjustable resistor is 0-100 after dialing down; the range of 0-1000 after dialing up.The right side of the down-dial switch of the potentiometer is set in units. Dial down to Sec. For seconds; dial up to Min. For minutes.3. Start button:Connect the self-reset button, press it once, switch to green light, indicating running status, the module will automatically work according to the set running time and stop time, infinite cycle. At this time, press the start button again, the module will switch to a red light, indicating that it is in a stopped state.4. Example of time setting:Requirements: 20 seconds on, 30 minutes off, infinite loop.Settings:(1) Dial down the running time range to 0-100;(2) Dial down the running time unit to seconds;(3) Rotate the running time potentiometer to 20 position, that is, 20/100 position from the left;(4) Dial down the stop time range to 0-100;(5) Dial up the stop time unit to minute;(6) Rotate the stop time potentiometer to 30 position, that is, 30/100 position from the left;Note: The position of the potentiometer can also be quickly located by measuring the voltage. The minimum adjustment of the central arm is 0V, and the highest position is 5V. For example, it needs to be adjusted to 20, that is, 20/100 * 5V = 1.0V; to be adjusted to 30, it is 30/100 * 5V = 1.5VOption description:Operating mode:(1) RD72-DC-A / Standard: Press the start button once to start the cycle, and then press the start button again to stop the work. The starting cycle mode is: on--off--on--off--(2) RD72-DC-AS / Enable version: Press and hold the button to start the infinite loop, release the button to stop the loop and jump to the disconnected state. The starting cycle mode is: on--off--on--off--.Package List:1 x Relay Module
  • ID Fruugo: 416675986-879151322
  • EAN: 7540131733857

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Etichette di sicurezza del prodotto

CE Mark
Avvertenze di sicurezza: Warning: Please read the product instructions carefully before use to ensure correct use.
Numero di serie: 7540131733857

Consegne e Resi

Spedito entro 2 giorni

  • STANDARD: GRATIS - Consegna tra gio 23 ottobre 2025–gio 30 ottobre 2025 - GRATIS

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa

Dettagli sulla conformità del prodotto

Si prega di consultare le informazioni di conformità specifiche per questo prodotto descritte di seguito.

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Produttore:
Le seguenti informazioni sono i dati di contatto del produttore del prodotto rilevante venduto su Fruugo.

  • Wuhan Pinsheng Technology Co., Ltd.
  • Wuhan Pinsheng Technology Co., Ltd.
  • No.A357,Shoulder-to-shoulder?Incubator,Building?4
  • Wuchang District
  • Wuhan
  • CN
  • 430000
  • pinsenkj@163.com
  • 18062524796
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Persona responsabile nell'UE:
Le seguenti informazioni sono informazioni dei contatto della persona responsabile nell'UE. La persona responsabile è l'operatore economico designato con sede nell'UE, responsabile degli obblighi di conformità relativi al prodotto in questione venduto nell'Unione Europea.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795