Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

8,95 €
+ 10,49 € Spedizione

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • Marchio: Unbranded
Venduto da:

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors

  • Marchio: Unbranded
Prezzo di vendita consigliato: 26,95 €
Prezzo: 8,95 €
Risparmi: 18,00 € (66%)
Venduto da:
8,95 €
+ 10,49 € Spedizione

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

Item Type:Relay Module_x000D_ Product Model: YF-11_x000D_ Input Voltage:DC7~24V_x000D_ Output Power: Can Control DC Power Load within 10A_x000D_ Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable_x000D_ Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch_x000D_ Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc._x000D_ P-21: Give the signal, after a delay of A second, the output starts_x000D_ P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops_x000D_ P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops_x000D_ P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops._x000D_ P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second_x000D_ P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second._x000D_ P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal)_x000D_ P-28: After power on, after a delay of A second, the output starts until the power is off_x000D_ P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops_x000D_ P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop_x000D_ P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop_x000D_ P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds_x000D_ P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds_x000D_ P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped._x000D_ P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within A+B time_x000D_ P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops_x000D_ P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time_x000D_ P-42: The signal disappears, after a delay of time A, the output starts; working time B ends_x000D_ P-43: The signal disappears. After the time A exceeds, the output starts; the working time B ends_x000D_ P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop._x000D_ P-45: No action when energized, after signal is given; output starts A time, stops B time; cycle C times and automatically stops; Give signal again, execute again_x000D_ P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off_x000D_ P-47: After giving the signal more than A times, the output starts and stops for B seconds_x000D_ P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds_x000D_ 3. Description of button setting:_x000D_ Power on display "" means entering standby state;_x000D_ Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function_x000D_ Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)_x000D_ Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)_x000D_ Press K1 for the fourth time, the display "" means entering the standby state_x000D_ Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption mode_x000D_ 4. The decimal point time unit description:_x000D_ X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds_x000D_ XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds_x000D_ XXX has no decimal point, timing range: 1 second to 999 seconds_x000D_ XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes
  • ID Fruugo: 314565398-701223214
  • EAN: 3851969966695

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Avvertenze di sicurezza: Do not let your children touch this product alone to avoid swallowing or other injuries.

Consegne e Resi

Spedito entro 3 giorni

  • STANDARD: 10,49 € - Consegna tra mar 21 ottobre 2025–mar 28 ottobre 2025

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa

Dettagli sulla conformità del prodotto

Si prega di consultare le informazioni di conformità specifiche per questo prodotto descritte di seguito.

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Produttore:
Le seguenti informazioni sono i dati di contatto del produttore del prodotto rilevante venduto su Fruugo.

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

Persona responsabile nell'UE:
Le seguenti informazioni sono informazioni dei contatto della persona responsabile nell'UE. La persona responsabile è l'operatore economico designato con sede nell'UE, responsabile degli obblighi di conformità relativi al prodotto in questione venduto nell'Unione Europea.

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611