Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

33,95 €
+ 11,99 € Spedizione

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

  • Marchio: Unbranded
Venduto da:

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC12‑24V

  • Marchio: Unbranded
Prezzo di vendita consigliato: 74,00 €
Prezzo: 33,95 €
Risparmi: 40,05 € (54%)
Venduto da:
33,95 €
+ 11,99 € Spedizione

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

Features: 1、PROGRAMMABLE FUNCTION: This offline sequence controller has programmable function, which can be customized to set up a great sequence trace according to actual requirements. 2、BASIC VALUES: This programmable offline sequence controller has an operating voltage of DC12 to 24V, a screen structure of 5 digits and a high brightness digital tube. 3、USE SCENARIO: Our programmable off line serial controller is widely applied in industrial automation control, small mechanical devices. 4、MADE OF PC MATERIAL: The programmable offline sequence controller is made of PC material, which is strong and durable. 5、LIGHT WEIGHT: Our programmable offline sequence controller is light weight and easy to install and very practical and helpful. Specification: Item Type: Programmable controller Material: PC Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H) Screen Structure: 5 digit, high brightness digital tube Operating Environment: -5℃- 60℃ (no condensation) Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W) Input: 5 programmable inputs, 2 fixed inputs Serial number Function Range Default value F0 Cycle working times Unit: times (demonstrated below)    0-65534, 65535 for countless times 1 F1 Number of rows at the beginning of the loop Unit: rows (Demonstrated below) 0-40 0 If the number of lines at the beginning of the loop > the number of lines at the end of the loop, it is illegal. Will alarm F2 Number of rows at the end of the loop Unit: rows (demonstrated below) 0-40 40 Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarm F3 Open [Output] manual debugging interface (restart to exit automatically or press [Return]) Introduced below 0 F4 Open [Input] manual debugging interface (restart to exit automatically or press [Return]) Introduced below 0 F5 Turn on programming mode (restart to exit automatically) 0-1 0 If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm 0: Turn off programming privileges (power off automatically changes to 0)  1: Turn on programming privileges F15 Adjust the amplitude value of [overall working time] during operation  Unit:second 0-65535.999 , 0=no speed change during operation 0 F16 Auto run at power on specified program line: 31-40 lines 0-2 0 0 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category 1 Power on automatically runs program segment 31-40 lines.  2 The power on automatically works. F17 Action when ESC emergency stop key is pressed 0-2 0 0 Program ends and turns off all outputs    1 Program ends and holds current state 2 Program ends and runs program segment lines 31-40 If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categories F18 Selectively switch P interface or F interface   0-3 0 1 Off [P interface] on [F interface]  2 On [P interface] off [F interface] 3 All off (temporary open: press [Set] key before power on)  0 All on F19 Main interface display content     0-2 0 0 Realtime working status. Display the total number of working times (not the number of cycles) under standby   1 Displays the number of cycles (not the total number)  2 Displays what line of program the system is running F20 Port filtering time of input port     0-65535 120 Set again when there is external interference. The higher the value, the slower the response Unit: Level F21 Start or emergency stop button signal filtering time on the panel   0-65535 27 Set again when there is external interference. The higher the value, the slower the response Unit: Level F24 Restore the factory setting     0-4 4 Note: After changing this parameter, you need to power off and restart 1 Restore [F] parameter only  2 Restore [P] parameter only 3 Restore all  4 No need to restore    0 or >10: restore all and open self test mode, factory mode (only for factory use) Package List: 1 x Programmable Controller
  • ID Fruugo: 399491312-850655727
  • EAN: 6930572179474

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Avvertenze di sicurezza: Do not let your children touch this product alone to avoid swallowing or other injuries.

Consegne e Resi

Spedito entro 24 ore

  • STANDARD: 11,99 € - Consegna tra gio 23 ottobre 2025–gio 30 ottobre 2025

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa

Dettagli sulla conformità del prodotto

Si prega di consultare le informazioni di conformità specifiche per questo prodotto descritte di seguito.

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Produttore:
Le seguenti informazioni sono i dati di contatto del produttore del prodotto rilevante venduto su Fruugo.

  • 91440300MA5GBP4X46
  • Shenzhen Qisheng Network Information Technology Co., Ltd.
  • Qianhai Kexing Science Park, Building 8, Room 1703
  • Laodong Community, Xixiang Street, Bao'an District
  • Shenzhen
  • CN
  • 518101
  • 1436389548@qq.com
  • 15089583894

Persona responsabile nell'UE:
Le seguenti informazioni sono informazioni dei contatto della persona responsabile nell'UE. La persona responsabile è l'operatore economico designato con sede nell'UE, responsabile degli obblighi di conformità relativi al prodotto in questione venduto nell'Unione Europea.

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611