FV-3KHz10V Frequency Voltage Converter Module 0~3Khz to 0~10V Digital to Analog Signal Module

17,07 €
spedizione GRATUITA

FV-3KHz10V Frequency Voltage Converter Module 0~3Khz to 0~10V Digital to Analog Signal Module

  • Marchio: Unbranded
Venduto da:

FV-3KHz10V Frequency Voltage Converter Module 0~3Khz to 0~10V Digital to Analog Signal Module

  • Marchio: Unbranded
Prezzo di vendita consigliato: 29,27 €
Prezzo: 17,07 €
Risparmi: 12,20 € (41%)
Venduto da:
17,07 €
spedizione GRATUITA

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

Features 1、The 0-3KHz frequency pulse signal is converted into a 0-10V analog voltage signal by this module. 2、The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. 3、Input pulse level of 5V 12V 24V can be input directly without string resistance.But the input signal frequency, to maintain more than 0.5 seconds, the output current is 5mA. 4、The multi-coil potentiometer on the board is used to calibrate the corresponding relationship between frequency and voltage. 5、The optical isolate is used to ensure the anti-interference ability of the signal input. Specification Features: The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. Input pulse level of 5V 12V 24V can be input directly without string resistance.But the input signal frequency, to maintain more than 0.5 seconds, the output current is 5mA. The optical isolate is used to ensure the anti-interference ability of the signal input. Specification: Size:4.5 x 4.7 x 1.7cm / 1.77 x 1.85 x 0.67in Relationship,Linearity: 300Hz to 1V 1.5Khz to 5V 3Khz to 10V Package List: 1 x Converter Module Note: For use with PLC, support for NPN type. Must have a ground wire. If you need to use an encoder, you need to keep the encoder running at a constant speed for more than 0.5 seconds. If the signal input is turbine flow, etc., due to signal matching, an 817 diaphragm and a resistor must be added to match the flowmeter to function properly. If there is a deviation in the correspondence when using, you can adjust the blue potentiometer on the board to calibrate. At the time of shipment, we have adjusted the F/V potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself. Package List
  • ID Fruugo: 271639001-602151488
  • EAN: 9308869116605

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Etichette di sicurezza del prodotto

CE Mark
Avvertenze di sicurezza: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

Consegne e Resi

Spedito entro 2 giorni

  • STANDARD: GRATIS - Consegna tra lun 13 ottobre 2025–ven 17 ottobre 2025 - GRATIS

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa