Temperature Controller Switch Aquarium Machine Electronic Digital Display Microcomputer

13,95 €
+ 0,99 € Spedizione

Temperature Controller Switch Aquarium Machine Electronic Digital Display Microcomputer

  • Marchio: Unbranded
Venduto da:

Temperature Controller Switch Aquarium Machine Electronic Digital Display Microcomputer

  • Marchio: Unbranded
Prezzo di vendita consigliato: 21,95 €
Prezzo: 13,95 €
Risparmi: 8,00 € (36%)
Venduto da:
13,95 €
+ 0,99 € Spedizione

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

1、Mini and light weight design. Large and clear LCD display screen. 2、Dual heating and cooling functions, automatic over‑temperature alarm. Control the temperature by setting the temperature setting value and different values. 3、The mini temperature controller is an excellent and convenient multi‑function device for controlling the temperature of the aquarium. The stability of aquarium temperature is one of the key factors to promote fish healthy and safety. 4、By using the temperature controller, you can provide the best temperature environment for your fish. This advanced temperature controller can measure and control temperatures from ‑50 to 90℃ 1 x Temperature Controller1 x Instruction Condition: 100% brand newItem type: Temperature ControllerMaterial: ABS flame retardant plastic caseColor: As picture shownWeight: Approx. 130g Power supply voltage: 110-220VAC ± 10%, 50/60Hz (or DC12V / DC24V)Measuring and controlling temperature range: -50℃~+110℃Resolution: 0.1°CAccuracy: ±1℃Accuracy: ±1℃Relay output contact capacity:Heating: 10A/240VAC,Cooling: 10A/240VCASensor h type: imported NTC sensor, cable length 1m/ 3.3ftDescription:P 0. Cooling and heating modePlease set to C for high temperature start as cooling modeLow temperature start is heating mode, please set to HP 1. Hysteresis settingIn heating mode (H): the measured value ≤ the set value-when the hysteresis starts to output the heating to the set value and stops.In the cooling mode (C): when the measured value ≥ the set value + hysteresis, the output cooling is started and the set value stops.P 2. The highest setting range: the highest value does not exceed this value when setting the temperatureP 3. The lowest setting range: the lowest value when setting the temperature is not lower than this valueP 4. Temperature correctionWhen there is a deviation between the measured temperature and the standard temperature, you can use this function to correct. The corrected temperature = the temperature before correction + the corrected value.P 5. Delay start time unit: minuteWhen controlling the refrigeration of the compression engine equipment, the delay time can be set according to the needs. The equipment will not start immediately when the controller is output, and it needs to start after the set delay time is run.P 6. High temperature alarmWhen the measured value is greater than this value, the screen displays --- and an alarm will sound, and the output will be forcibly disconnected.P 7. Data lock functionTurn on the data lock to keep the current setting unchanged. At this time, the set temperature and function are invalid. If you need to modify it, you need to turn off the data lock function.P 8. Restore factory settingsLong press SET to switch to P8, press SET once to set to on, press for Rst to restore factory settingsYou can also press and hold the +-key and hold the power-on self-test and restore factory settings.Instructions for usePlease connect the power supply according to the parameters and wiring diagram, and connect the cooling or heating equipment to the output terminal.Enter the internal settings to select heating (enter P0 to select H) or cooling (enter P0 to select C) mode as needed.Setting temperature method: press Set once and the screen flashes, press up and down to set the desired temperature, press for Rst to confirm and return to the OUT indicator of the panel: flashing indicates the delay of cooling or heating start, and constant light indicates outputNixie tube: display LLL for open circuit of the sensor; display for HHH for exceeding the measuring range and the thermostat will be forced to power off; display --- for high temperature alarm.
  • ID Fruugo: 355057006-771892000
  • EAN: 9790283540560

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Avvertenze di sicurezza: WARNING: Opening and/or repairing your device may result in risk of electric shock, damage to the device, fire and personal injury, and other hazards. We recommend that you seek professional assistance for device repairs and exercise caution when repairing your device yourself.

Consegne e Resi

Spedito entro 3 giorni

  • STANDARD: 0,99 € - Consegna tra gio 16 ottobre 2025–lun 20 ottobre 2025

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa

Dettagli sulla conformità del prodotto

Si prega di consultare le informazioni di conformità specifiche per questo prodotto descritte di seguito.

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Produttore:
Le seguenti informazioni sono i dati di contatto del produttore del prodotto rilevante venduto su Fruugo.

  • Ma LunYin
  • Lixian Runda Trading Co.,Ltd.
  • Group 5
  • Xujiapu Village
  • Changde city
  • CN
  • 415518
  • baishouqibc@outlook.com
  • 13067021674

Persona responsabile nell'UE:
Le seguenti informazioni sono informazioni dei contatto della persona responsabile nell'UE. La persona responsabile è l'operatore economico designato con sede nell'UE, responsabile degli obblighi di conformità relativi al prodotto in questione venduto nell'Unione Europea.

  • e Vatmaster Consulting GmbH
  • e Vatmaster Consulting GmbH
  • RaiffeisenstraBe 2 B11
  • Rodgau
  • DE
  • 63110
  • contact@evatmaster.com
  • 49 61062699873