Variable Frequency Drive 1.5KW 2HP Universal Vector Inverter 1PH AC220V Input 3PH 0‑220V Output

240,93 €
spedizione GRATUITA

Variable Frequency Drive 1.5KW 2HP Universal Vector Inverter 1PH AC220V Input 3PH 0‑220V Output

  • Marchio: Unbranded
Venduto da:

Variable Frequency Drive 1.5KW 2HP Universal Vector Inverter 1PH AC220V Input 3PH 0‑220V Output

  • Marchio: Unbranded
Prezzo di vendita consigliato: 530,03 €
Prezzo: 240,93 €
Risparmi: 289,10 € (54%)
Venduto da:
240,93 €
spedizione GRATUITA

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

1、SPECIFICATIONS: The input voltage is 1PH AC220V, the output voltage is 3PH AC0-220V, used for 1.5KW 2HP motors to achieve motor speed regulation function. 2、HEAT DISSIPATION: The frequency converter adopts independent air duct design to quickly export heat to achieve cooling effect and prevent the machine from overheating. 3、ABS HOUSING: The inverter housing is made of ABS plastic, which is heat resistant, impact resistant, and flame retardant, ensuring safe and reliable operation. 4、GOOD PERFORMANCE: Integrated IGBT module is adopted, with strong load carrying capacity and good stability, dual row digital tube display, has large low frequency torsion. 5、MACRO FEATURE: Can realize the one button constant pressure water supply macro, engraving machine macro, and machine tool macro function, which is efficient and stable. Item Type: Frequency Inverter Material: Flame Retardant ABS Input: 1PH AC220V±15% 14.0A 50-60Hz Output: 3PH AC0-220V 7.0A 0-400Hz Power Capacity: 3.0KVA Suitable Motor: 1.5KW 2HPOvervoltage Suppression Protection: When the bus voltage reaches or exceeds the bus overvoltage suppression point during the operation of the frequency converter, the frequency converter will automatically adjust the operating frequency to suppress the rise of the bus voltage, thereby ensuring that the frequency converter does not cause overvoltage protection due to excessive bus voltage. Overcurrent Suppression Protection: During operation, through real time monitoring of the load current, it automatically limits it to not exceed the set overcurrent suppression point to prevent fault tripping caused by excessive current. This function is particularly suitable for loads with large inertia or severe changes. TypeTerminal SignTerminal NameDescriptionPowerSupply10V GNDExternal +10V Power SupplyExternal supply of +10V power supply, maximum output current: 150mA (with short circuit protection) Generally used as an external potentiometer working power supply, Potentiometer resistance range: 1-5kΩ 24V COMExternal +24V Power SupplyExternal supply of +24V power, generally usedas digital input and output terminals Power supply and external sensor power supply Maximum output current: 200mA Analog TerminalAl1 GNDAnalog Input Terminal 1Input Range: DC0-10V 0-20mA, determined by parameter P437 Input Impedance: 22kΩ for voltage input, 500Ω for current input Al2 GNDAnalog Input Terminal 2Input Range: DC0-10V 0-20mA, determined by parameter P4-37 Input Impedance: voltage input impedance 22kQ, current input impedance 500Ω AO1 GNDAnalog Output Terminal 1Output Voltage Range: 0V-10V Output Current Range: 0mA-20mA, 4-20mA (P5-23 selectable) AO2 GNDAnalog Output Terminal 2Output Voltage Range: 0V-10V No current output function J1 jumper cap on isolated main control board to AO2 position, non isolated main control board The control board does not have this function Digital InputX1 COMDigital Input 1HD1 (X5) can also be used as a high speed pulse input channel in addition to X1-X4 features Maximum input frequency: 50kHz Input impedance: 1kΩ Voltage range at level input: 5V-30V X2 COMDigital Input 2X3 COMDigital Input 3X4 COMDigital Input 4HDI COM (X5 Terminal)Digital input 5 High Speed Pulse Input Terminal A+ B-RS485 CommA+ is the positive input of the 485 communicationdifferential signal, B- is the negative input of the differential signalDigital OutputY1 COMOpen Collector OutputWhen used as a collector open circuit output terminal (J1 jumper cap on the 90 isolated main control board to the AO2 position)HDO COMHigh Speed Pulse OutputRestricted by the function code P5-00 HDO terminal output mode selection, output as a high speed pulse with a maximum frequency of 50kHz; When output as a collector open circuit, the same as Y1K1A K1B K1CRelay 1 TerminalContact Description: A: Common Point, B: Normally Closed Point, C: Normally Open Point Contact Driving Capacity: AC250V, 3A; DC 30V, 1A K2A K2B K2CRelay 2 Terminal 1 x Frequency Converter 1 x User Manual
  • ID Fruugo: 347772530-759807025
  • EAN: 627218896838

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Etichette di sicurezza del prodotto

CE Mark
Avvertenze di sicurezza:
  • Not suitable for children under 36 months
  • Choking Hazard
  • Adult supervision recommended

Consegne e Resi

Spedito entro 2 giorni

  • STANDARD: GRATIS - Consegna tra mer 15 ottobre 2025–gio 23 ottobre 2025 - GRATIS

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa