Item Type: Incubator Temperature Controller
Material: ABS
Power Supply Voltage: AC110-230V
Power Supply Frequency: 50/60Hz
Temperature Measurement Range: -40-110
Temperature Measurement Accuracy: 0.3
Humidity Measurement Range: 0%-100%RH
Humidity Measurement Accuracy: 3%
Output Control: Relay Output
Output Power: Mximum 10A
Installation Hole Size: Approx. 28 x 70mm/1.1 x 2.8in
Setup essential
Start value Stop value (The program automatically determines that the working mode is cooling/dehumidifying mode)
Heating/cooling mode setting
Setting method:
Setting (start temperature): long press the 1 button, the start temperature flashes, and set the start temperature value through the 11 key
Setting (stop temperature): long press the 1 button to stop the temperature flashing, and set the stop temperature value through the 11 button.
Heating use case:
Control the water heater, stop heating to 70C, start heating again when the temperature drops to 45C, and cycle
Step 1: Heating working mode, starting temperature stop temperature
Step 2: Long press the 1 button, the start temperature flashes, and set the start temperature to 30 by pressing the 11 button
Step 3: Long press the 1 button to stop the temperature flashing, and set the stop temperature to 25 through the 1 button, and the setting is complete! If there is no operation for 10 seconds, it will automatically return to the normal display state. You can also press 22 to exit immediately.
Humidification/dehumidification mode setting
Setting method:
Setting (starting humidity): long press the 2 key, the start humidity value flashes, and set the start humidity value through the 22 key.
Setting (stop humidity): Long press the 2 key to stop the flashing of the humidity value, and set the stop humidity value through the 22 key.
Humidification example:
To humidify the supermarket, control the humidifier to 50% RH to start humidifying, and to stop humidifying when humidified to 80% RH.
Setting steps:
Step 1: Long press the 2 key to start the humidity value flashing, and use the 22 key to set the start humidity value to 50%RH
Step 2: Long press the 2 key to stop the humidity value flashing, and set the stop humidity value to 80%RH through the 22 key, and the setting is complete! Press the key for 10 seconds without operation, it will automatically return to the normal display state, or you can press the 11 key to exit immediately.
Dehumidification example:
Workshop control exhaust dehumidification system, humidity 75%RH starts dehumidification, humidity 45%RH stops dehumidification
Setting steps:
Step 1: Long press the 2 key to start the humidity value flashing, and use the 22 key to set the starting humidity value to 75%RH
Step 2: Long press the 2 key to stop the humidity value flashing, and set the stop humidity value to 45%RH by pressing the 22 key, and the setting is complete! Press the key for 10 seconds with
-
Fruugo ID:
422357873-888850985
-
EAN:
6903379086382
Delivery & Returns
Dispatched within 3 days
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy