Description
HP7200B TRMS Clamp Meter 6000 Counts 26mm NCV Voltage Resistance
HP7200B TRMS Clamp Meter 6000 Counts NCV Dc AC Voltage Resistance Temperature Multimeter
Condition:
Item Type: Clamp Meter
Material: ABS
General Characteristics
Maximum Display
6000
Measuring Principle
Double integral A/D conversion
Sampling Rate
2~3 times per second
Polarity Display
Negative polarity input shows "-"
Over-Range Display
Display "OL" or "-OL"
Low Battery Display
Display symbols
Auto Range Function
Automatic Shutdown Function
About 15 minutes after power-on, the meter will automatically shut down, press any key or turn the function selection switch to turn it on again. Press and hold the "SEL" key to turn on the device to release the automatic shutdown function.
Safety Standard
The instrument has passed the IEC-1010 double insulation, environmental pollution degree 2 degree, overvoltage category CAT Ⅱ 600V or CAT Ⅲ 300V safety standard promulgated by the International Electrotechnical Commission.
Working Environment
Temperature 0-40℃, relative humidity≤80%
Storage Environment
Temperature -20-60℃, relative humidity ≤90%
Power Supply
2 x AAA dry batteries (not included)
Clamp Head Opening Size
26mm/1in
Parameter
DC Voltage (DCV)
Range
Resolution
Accuracy
600mV
0.1mV
±(0.5% reading + 2 digits)
6V
1mV
±(0.5% reading + 2 digits)
600V
100mV
±(0.8% reading + 2 digits)
Overload Protection
600V DC or AC RMS
Input Resistance
10MΩ, 600mV range is greater than 100MΩ
AC Voltage (ACV) (True RMS)
Range
Resolution
Accuracy
6V
1mV
±(1.0% reading + 3 digits)
60V
10mV
±(1.0% reading + 3 digits)
600V
100mV
±(1.5% reading + 3 digits)
Overload Protection
600V DC or AC RMS
Input Resistance
10MΩ
Measuring Frequency Range
40-2kHz
DC Current (DCA)
Range
Resolution
Accuracy
60A
10mA
±(2.5% reading + 10 digits)
400A
100mA
±(3.0% reading + 10 digits)
Overload Protection
400A DC or AC RMS
AC Current (ACA) (True RMS)
Range
Resolution
Accuracy
60A
10mA
±(2.5% reading + 10 digits)
400A
100mA
±(3.0% reading + 10 digits)
Overload Protection
400A DC or AC RMS
Measuring Frequency Range
40-100Hz
Resistance (Ω)
Range
Resolution
Accuracy
600Ω
0.1Ω
±(1.0% reading + 3 digits)
6kΩ
1Ω
±(1.0% reading + 2 digits)
60kΩ
10Ω
±(1.0% reading + 2 digits)
600kΩ
100Ω
±(1.0% reading + 2 digits)
6MΩ
1kΩ
±(1.0% reading + 2 digits)
60MΩ
10kΩ
±(1.5% reading + 3 digits)
Overload Protection
250V DC or AC RMS
Capacitance (CAP)
Range
Resolution
Accuracy
6nF
1pF
±(5.0% reading + 10 digits)
60nF
10pF
±(3.0% reading + 10 digits)
600nF
100pF
±(3.0% reading + 10 digits)
69μF
1nF
±(3.0% reading + 10 digits)
60μF
10nF
±(5.0% reading + 10 digits)
600μF
100nF
±(10.0% reading + 20 digits)
6mF
1μF
±(10.0% reading + 20 digits)
60mF
10μF
±(10.0% reading + 20 digits)
Overload Protection
250V DC or AC RMS
Frequency (Hz)
Range
Resolution
Accuracy
9.999Hz
0.001Hz
±(0.1% reading + 5 digits)
99.99Hz
0.01Hz
±(0.1% reading + 5 digits)
999.9Hz
0.1Hz
±(0.1% reading + 5 digits)
9.999kHz
1Hz
±(0.1% reading + 5 digits)
99.99kHz
10Hz
±(0.1% reading + 5 digits)
999.9kHz
100Hz
±(0.1% reading + 5 digits)
9.999MHz
1kHz
±(0.1% reading + 5 digits)
Test Sensitivity
0.6V AC RMS (9.999MHz file: 1.5V AC RMS)
Overload Protection
250V DC or AC RMS
Duty Cycle
Measuring Range
0.1%~99.9%
Accuracy
±(2.0% reading + 2 digits)
The frequency is lower than 10kHz, higher than 10kHz can not guarantee accuracy
Sensitivity
0.6V AC RMS
Overload Protection
250V DC or AC RMS
Temperature (℃/℉)
Range
Resolution
Accuracy
-20-150℃
1℃
±(3℃ + 1 digits)
150-1000℃
1℃
±(3% reading + 2 digits)
-4-302℉
1℉
±(5℉ + 2 digits)
302-1832℉
1℉
±(3% reading + 3 digits)
NiCr-NiSi K Type Thermocouple
Overload Protection
250V DC or AC RMS
Diode Detection
Resolution
1mV
Function
Read the forward voltage across the diode at an instant
Overload Protection
250V DC or AC RMS
Instantaneous DC Current
About 1.5mA
Reversed DC Voltage
About 4V
On-Off Detection
When the resistance of the component or loop under test is less than 50Ω, the buzzer will sound and the flashlight will light up at the same time
Overload Protection
250V DC or AC RMS
Open Circuit Voltage
About 2V
Non-Contact AC Voltage (NCV) Detection
Detection Voltage Range
90V-1000V AC RMS
When an AC voltage signal is sensed, the flashlight will light up and the buzzer will sound.
-
Fruugo ID:
407590100-863778644
-
EAN:
4691329920474
Delivery & Returns
Dispatched within 24 hours
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy