DPS3005 Communication Version Buck Power Supply Step Down Voltage Converter(DPS3005 )

80,51 €
spedizione GRATUITA

DPS3005 Communication Version Buck Power Supply Step Down Voltage Converter(DPS3005 )

  • Marchio: Unbranded

DPS3005 Communication Version Buck Power Supply Step Down Voltage Converter(DPS3005 )

  • Marchio: Unbranded
Prezzo di vendita consigliato: 92,71 €
Prezzo: 80,51 €
Risparmi: 12,20 € (13%)
Venduto da:
80,51 €
spedizione GRATUITA

Disponibile

Accettiamo i seguenti metodi di pagamento

Descrizione

Specification: Model(Optional) DPS3005 DPS5005 Input voltage 6.00-40.00V 6.00-55.00V Output voltage 0V-32.00V 0V-50.00V Output current 0-5.000A 0-5.000A Output power 0-160.0W 0-250.0W Voltage resolution 0.01V 0.01V Current resolution 0.001A 0.001A Size 80*44*45mm/3.1*1.7*1.8in Weight Approx.138g/4.9oz Connection description IN+: Input positive, IN-: Input negative: OUT+: Output positive, OUT-: Output negative Note: Input voltage range is DC 6-40V and 40v is the limit voltage; please leave a room to use. Or else it will be burnt. The input must be DC power supply, not AC 220V, or else it will be burnt too. Though this module has reverse connection protection and output short circuit protection, you can muse be in strict accordance with connection description to connect. If you connect the supply power with output, the module will be burnt. Operating instructions When connect the power supply, the screen shows welcome window firstly and then comes into main interface. Set the output voltage and output current on the main interface. Press V/UPkey shortly, you can enter into voltage setting status. Then press the coding potentiometer, and then enter to adjust the numerical value. Press coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clockwise rotation to increase the numerical value; Turn by counterclockwise to decrease the numerical value. If you want to exit adjusting the numerical value, press shortly V/UP. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too. You can press A/Downto set the output current by the same way. Set the data on the data setting interface On the main interface, you can press SET key shortly to enter into data setting interface. On the data setting interface, press shortly V/UPor A/Down to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface . Set the protection value. Page up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value , over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed. And then press shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, press shortly SET key. Adjust the brightness of screen. Page up or page down to B-LED, and then press shortly the coding potentiometer to enter into the status of adjusting the brightness of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, press shortly SET key. There are six brightness levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like. Data setting and store the specified data group. Page up or page down to M-PRE, and then press shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then press the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, press shortly SET key. Then press shortly V/UPor A/Down to page up or page down to other place to adjust the data you need. After data setting done, keep pressing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can press shortly SET key back to the main interface. Set default boot open or close output Page up or page down to S-INI, and then press shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close. Package list: 1 x Step-Down Module 1 x blueteeth board 1 x USB board 1 x communication cable
  • ID Fruugo: 348510758-760853403
  • EAN: 9321090829953

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Etichette di sicurezza del prodotto

CE Mark
Avvertenze di sicurezza: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

Consegne e Resi

Spedito entro 2 giorni

  • STANDARD: GRATIS - Consegna tra ven 03 ottobre 2025–gio 09 ottobre 2025 - GRATIS

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa